An irrigation pump that fails in midsummer costs far more than the part that broke. Most pump failures give warnings first: a change in noise, heat, vibration or leakage. Regular greasing, a look at the packing and a yearly check of the electrical side catch most of them. This article collects the intervals and limits that two extension publications give for motors, bearings, packing, pumps and engines.
Motors and electrical checks #
Make sure the motor is bolted down, because mounting bolts can vibrate loose. Motors that run at 3,600 rpm wear about twice as fast as motors at 1,800 rpm1. Greasing follows the maker’s directions, and a publication1 gives these typical intervals:
- Normal duty, up to 8 hours a day: every 8 months for motors of 1 to 9 hp (0.7 to 6.7 kW), every 6 months for 10 to 40 hp (7.5 to 30 kW) and every 4 months for 50 to 150 hp (37 to 110 kW).
- Heavy duty, up to 24 hours a day: every 4, 3 and 2 months for the same three sizes.
Over greasing and under greasing can both ruin bearings. Check electrical connections twice a year for corrosion and tightness. If compressed air is used for cleaning, keep it at 50 psi (3.4 bar) or less1. An electrician can run an insulation test on the panel, motor and wiring, which can find moisture in the windings. Current as low as 15 milliamps can cause serious injury, so power is disconnected before any work12. Never use the main disconnect to start or stop the motor1.
Bearings and lubrication #
On turbine pumps, change the upper bearing oil at the start of the season. Vertical hollow shaft motors get a yearly oil change with ISO VG 32 turbine oil, and the oil level has to stay correct because an overfilled bearing can spill onto the motor and make it run hotter1.
Packing and seals #
Packing needs a small leak to stay cool. Check it daily, and aim for about 8 to 10 drops a minute. At start up, tighten the gland nuts slightly every 15 to 20 minutes until the leak falls to that rate. Grease the packing box each year. If the leak cannot be reduced by adding a ring, or if the packing is burned, replace it. A shaft sleeve that is worn or grooved should be replaced too1. Seals, gaskets and connections should also be checked for leaks2.
The pump itself #
- Before the first start, turn the shaft by hand. Power applied to a rusted impeller can break it1.
- Clean the suction and discharge piping and the trash screens twice a year1.
- Do not run the pump for more than two minutes with the discharge valve closed1.
- Keep suction lift under 15 to 20 ft (4.5 to 6 m). Suction line velocity should be 5 ft per second (1.5 m per second) or less, and discharge line velocity under 7 ft per second (2.1 m per second)1.
- Check the impeller eye and vanes for wear. A wear ring with more than 1/32 in. (0.8 mm) clearance on each side should be re-machined or replaced. Cavitation pits the impeller and casing and lowers pump capacity1.
Excessive vibration or noise can point to worn bearings, impeller damage, cavitation or misalignment2. A qualified pump technician should inspect an irrigation pumping system every three to five years. After the season, remove the pump drain plug, because water left inside can freeze and crack the pump, and reinstall it before the next season2.
Diesel engines #
Change the crankcase oil and the filter twice a year if the engine was not protected during shutdown, or if the oil was not changed in the last year. Use the oil the maker recommends. After a start, run the engine for 10 minutes and then check the oil and coolant levels. Engines also lose power in the field: about 3.5% for every 1,000 ft (300 m) of elevation above 500 ft (150 m) and about 1% for each 10°F (5.6°C) above 85°F (29°C)1. An engine sized without that margin will run at its limit on hot days.
Practical tips #
Keep a log with the date of each greasing, oil change and repair, along with the pressure and flow at the pump. Gauges often fail, so check them against a known good one2. Test the low oil and high temperature shutdowns before the season. The center pivot maintenance checklist covers the rest of the system, and the article on winterizing covers the end of the season.
The usual mistakes are skipping the daily look at the packing, greasing by the calendar without looking at the duty, and replacing parts without finding what wore them out.
Sources and further reading #
- Maintaining Irrigation Pumps, Motors, and Engines (IP299), National Center for Appropriate Technology (NCAT)
- Inspecting and maintaining irrigation systems (EM 9869), Oregon State University Extension