A variable frequency drive (VFD) lets an electric irrigation pump run at the speed the system needs at that moment, not at one fixed speed all the time. That can save energy and protect the pump, but it doesn’t always pay. Utah State warns that incentives sometimes lead to drives on pumps where the costs outweigh the benefits. This article explains what a drive does, what a study1 found for center pivots, how to turn those findings into a yearly figure for your own farm, and what to check before you buy.
What a VFD does #
A VFD is an electronic controller that changes the pump motor’s speed by changing the frequency of the electricity it receives. A pressure sensor on the system lets it hold a set pressure. Speed matters because of how pumps behave. Flow changes in proportion to speed, but power changes with the cube of it, so a modest drop in speed gives a much bigger drop in power use.
Why a pivot wastes energy at fixed speed #
A pumping plant for a center pivot is designed to deliver the needed flow and pressure to the highest point in the field with all the sprinklers running. Fields have some slope, but because the design covers the worst case, most of the field gets more pressure than it needs. The pump is working harder than necessary for much of every revolution, and the extra is wasted electricity. A drive slows the pump down whenever the system needs less.
What the study showed #
The study1 looked at 1,000 center pivots in ten counties. They laid a standard pivot on each field’s elevation map and calculated, by computer, how much electricity a drive would save. These are modelled estimates, not measurements from farms, and they rest on assumed designs, prices and a 15-year drive life.
The savings are given per hour the pump runs, as a reduction in the electricity bill. They depended mostly on what was on the end of the pivot:
- A plain pivot: under 0.25 dollars an hour, even on rolling ground.
- With an end gun: about 0.70 dollars an hour. The end gun works for only about 44% of each revolution, so the rest of the time the pump is pushing more than the pivot needs.
- With a corner extension: about 1.60 dollars an hour. The extension is fully working for only about 22% of each revolution, yet the pump has to be sized for it.
- With a corner extension and an end gun: about 3 dollars an hour on average.
The pattern is simple. A drive earns its money when the pump’s peak demand lasts only part of the time. A plain pivot has little excess to trim. One with a corner arm has a lot.
Turning dollars per hour into dollars per year #
To see what a drive means for you, multiply the savings per hour by the hours your pump runs in a season. Your electricity bills or the pump’s hour meter will tell you the hours. As an illustration only, take 600 hours a season. At 0.25 dollars an hour that is about 150 dollars a year. At 0.70 it is about 420, at 1.60 it is about 960, and at 3 dollars it is about 1,800. Your hours, your electricity price and the shape of your field will move these numbers up or down.
Then compare that yearly saving with what the drive costs you each year. That means the purchase and installation, any upgrades to the power supply, the interest if you borrow the money or lose it if you don’t, and upkeep. The study1 assumed a loan at 7% over the drive’s life. If the yearly saving is smaller than the yearly cost of owning the drive, it won’t pay for itself. Get a written quote before you decide, because the price depends on the size of the pump and what the site needs. The savings you can actually expect are not a guess: you can calculate them from the three numbers above.
The total cost of owning a drive #
Utah State adds a useful way to think about it. Over the life of a drive, the purchase price is only about 5% of the total cost. Operating it is usually 75 to 95%. And the cost of downtime, when it isn’t running and you can’t irrigate, can be 0 to 25%. So a cheap drive with weak support can cost far more than a dearer one that is reliable and backed by good service, because a failure in the middle of a hot spell is what really costs money. This is why Utah State tells buyers not to start with the price.
Benefits that don’t show up as dollars per hour #
The figures from the study1 count only energy. Utah State lists others. A drive reduces stress on the electrical system and on the pump, which can extend its life. It gives a soft start. It can trim the total load where several pumps share a main line. And it can make a single-phase supply usable for a three-phase motor, which can save the cost of running three-phase power to the field. These can make a drive worthwhile on its own, but they are hard to put a number on, so price them separately.
Be careful with incentives. Many energy companies and governments pay part of the cost, which Utah State says can lead to drives going on pumps where the costs outweigh the benefits. A grant lowers the price you pay, but it doesn’t change what the drive saves you.
Where to put the pressure sensor #
It matters. A sensor at the pump is often the worst place when the field has a lot of slope. In the fields of the study1, the best position was near the eighth tower in about half the cases, and near the seventh or sixth in most of the rest. Evaluate each pivot separately, and Utah State suggests placing the sensor near the last span, with telemetry if needed.
When a VFD makes sense #
Utah State lists the situations where a drive tends to earn its keep:
- The load varies on a pump, for example when several sprinkler systems or zones start at random times.
- Several pumps share one main line, and one drive can trim the total.
- The system needs a soft start and the load varies. A soft start alone isn’t a good enough reason.
- A smaller pump is needed and a drive costs less than pulling and re-bowling the existing one.
- You need to convert from single-phase to three-phase power.
- An old pumping system needs a major overhaul, or the system has changed and needs different flows or pressures.
What to check before you buy #
Ask how long the warranty lasts, what it covers, how fast claims are handled, whether parts are stocked nearby and where the nearest technician is. Ask about the model’s life cycle, and be wary of one nearing the end of its support. Most drives last 10 to 15 years.
Cooling and cleanliness affect that life. Fan cooling is the cheapest and simplest, but it lets in dust. Water cooling keeps the cabinet clean but has to be winterized. Air conditioning is cleanest and costs most. Most drives are designed for temperatures between about 32 and 104°F (0 and 40°C), so add heating or cooling if your site goes outside that. Protect the drive from dust, moisture, insects and rodents, and from power problems. Low-cost extras include line reactors, fast-acting fuses, voltage monitors and surge arresters.
Size the drive by current, not horsepower. Drives are often sold undersized, and most irrigation motors run overloaded, so ask about the pump’s full-load current, and about the condition of the motor. Test the motor windings first, because an old motor can damage a new drive. Heat, altitude and long cables can mean the drive needs a larger rating. And ask your supplier about harmonics, the electrical disturbance a drive causes in the supply, which can trip breakers and overheat equipment if it isn’t handled.
Check it with a calculator #
A free spreadsheet calculator from the US Natural Resources Conservation Service lets you enter your own pump, hours and electricity price and see whether a drive would be economical.
Keeping it healthy #
A simple sunshade extends the life of the drive. Keep cooling air intakes clean, because a little dirt heats the panel, and replace the filters as recommended. And keep the pressure sensor where it suits your pivot.
Sources and further reading #
- Economics of Variable Frequency Drives for Irrigation Pumps, University of Nebraska-Lincoln CropWatch
- Variable Frequency Drives for Irrigation Pumps, Utah State University Extension
- Irrigation Water Pumps (AE1057), North Dakota State University Extension