Water that looks clean can still block an emitter. Dissolved minerals, bacteria and algae build up slowly inside tubing, filters and nozzles, and the damage is usually found only when a field shows dry patches. A water analysis before the system is built tells what to expect and what treatment to plan. This article explains which numbers matter, what levels count as a problem and what is done about each one.
The numbers that matter #
A Kansas State publication1 on subsurface drip rates each water constituent as low, moderate or high concern for clogging:
- pH: low concern below 7, moderate from 7 to 8, high above 8
- Total dissolved solids: below 500 mg/L, 500 to 2,000 mg/L, above 2,000 mg/L
- Iron: below 0.2 mg/L, 0.2 to 1.5 mg/L, above 1.5 mg/L
- Manganese: below 0.1 mg/L, 0.1 to 1.5 mg/L, above 1.5 mg/L
- Hydrogen sulfide: below 0.2 mg/L, 0.2 to 2.0 mg/L, above 2.0 mg/L
- Bacteria: below 10,000 per mL, 10,000 to 50,000 per mL, above 50,000 per mL
- Suspended solids: below 50 mg/L, 50 to 100 mg/L, above 100 mg/L
The same publication notes that most Kansas water is fairly hard, and that calcium above about 2 to 3 meq/L can form solids when some phosphate fertilizers are injected1.
What each one does #
Hard water with high pH and bicarbonate drops calcium carbonate, a white scale, inside tubing and emitters. Iron and manganese turn into rust colored or dark deposits when the water meets air or chlorine, and they also feed iron bacteria. Hydrogen sulfide, which smells like rotten eggs, feeds sulfur bacteria. Bacteria and algae form slime that binds with sand and silt into plugs. Suspended solids are removed by filters, which the article on filtration for drip irrigation describes. The dissolved problems need chemistry.
Treatments and the numbers behind them #
The Kansas State publication1 lists these treatments:
- Scale from calcium carbonate, when bicarbonate is above 2 meq/L and pH above 7.5: inject acid continuously to hold pH between 5 and 7, or drop the pH below 4 for 30 to 60 minutes each day.
- Iron above 0.1 mg/L: aerate the water and let it settle, which works best at 10 mg/L or more. Another option is chlorine ahead of the filter at 1 ppm for each 0.7 ppm of iron.
- Manganese above 0.1 mg/L: chlorine ahead of the filter at 1 ppm for each 1.3 ppm of manganese. The solids may form downstream of the filter.
- Iron bacteria: chlorine at 1 ppm continuously, or 10 to 20 ppm for 30 to 60 minutes a day.
- Sulfur bacteria, with sulfide above 0.1 mg/L: chlorine at 1 ppm for each 4 to 8 ppm of hydrogen sulfide.
- Slime and algae: chlorine at 0.5 to 1 ppm continuously, or 20 ppm for 20 minutes at the end of each irrigation.
A worked example makes the rule clearer. Water with 1.4 mg/L of iron falls in the moderate concern range. Chlorine at 1 ppm per 0.7 ppm of iron means 1.4 divided by 0.7, so about 2 ppm of chlorine injected ahead of the filter. Chemicals have to be handled by the label and by local rules, and the injection equipment needs backflow protection, as the chemigation equipment article explains.
Wells and fertilizer #
Wells should be shock chlorinated at least once a year. The pumped water goes to waste until it runs clear, and it must never be sent through a drip system1. Fertilizer adds its own risk. A jar test shows whether a fertilizer will form solids in the water: mix at the planned strength, shake for one minute and leave for 15 minutes. Cloudiness means a likely plugging problem2.
Practical tips #
Order a full water analysis from a laboratory before choosing emitters and filters. Test again every year or two, since well water can change. Check the end of the last drip line for slime or scale at the start of the season. Choose emitter types and tubing with the results in hand, as covered in the article on drip emitters and tubing.
The usual mistakes are judging water by its appearance, treating only after the plugging begins and sending shock chlorinated well water through the lines.
Sources and further reading #
- Subsurface Drip Irrigation (SDI) Water Quality Assessment Guidelines (MF-2575), Kansas State University Agricultural Experiment Station and Cooperative Extension Service
- Fertigation Facts, Utah State University Extension