Ask any grower with a drip system what causes trouble, and the answer is nearly always the same: blocked emitters. The orifices are tiny, because that is how drip delivers very low flow rates, so even small particles can plug them. Florida Extension calls effective and reliable filtration mandatory for a drip system, and Oklahoma State says a system with poor water and poor filtration simply won’t work reliably enough to be worth the maintenance. This article covers the filter types, how to match one to your water, and how to keep it working.
What clogs an emitter #
Three things block emitters. Physical contaminants are suspended solids such as silt and sand. Chemical ones are minerals that precipitate out of solution, mainly iron and calcium. Biological ones are algae and bacterial slime. Oklahoma State notes that solids are usually less of a problem in groundwater than in surface water, while mineral precipitation is mostly a groundwater problem, because dissolved minerals can come out of solution when the pH or temperature changes or when the water is aerated.
Match the filter to the water #
Screen filters are simple and cheap, and they remove very fine sand and larger inorganic debris. They are a poor choice as the only filter on water with a heavy load of algae or other organic matter, because they clog fast and would need constant cleaning. On surface water they work best as a secondary filter after a media filter, where they stop media that has washed out from reaching the emitters. On well water a screen can be the primary filter, or it can follow a vortex sand separator when the water carries a lot of sand. A separator spins the water so heavy particles drop to the bottom of the unit, where they can be flushed away.
Disk filters are a hybrid. A stack of grooved plastic or epoxy-coated disks traps particles in the grooves as water passes through. Oklahoma State considers them right for moderately dirty water, relatively easy to flush and reuse, and moderately expensive. Media filters use graded layers of fine sand to remove sediment. Oklahoma State recommends them for water with large amounts of fine silt and clay. They handle very large flows and are effective, but they are relatively expensive to buy and maintain, and they are usually the choice for organic matter in surface water. Finer media removes more but needs more frequent backwashing, and filtration is less effective as the flow rate through the filter rises.
At the intake, a screen keeps aquatic plants, fish and animals out of the suction pipe. It should be a horizontal screen below the water surface or a basket-type intake, so that debris separates from the water without being pulled against the screen. Gravity screen filters, which use no pressure at all, suit an elevated canal or reservoir where you want to avoid pressure loss. Y-type strainers catch small amounts of larger particles.
Mesh sizes and particle sizes #
Screens are classified by the number of openings per inch. A 200 mesh screen has openings of about 74 microns and is used often in drip systems. It lets through only very fine sand or smaller particles. A publication1 gives these equivalents: 40 mesh is about 420 microns, 80 mesh about 180, 120 mesh about 125, 200 mesh about 74 and 270 mesh about 53. For reference, fine sand is 100 to 250 microns and very fine sand 50 to 100, while silt is smaller than 50 and screens aren’t normally used to remove it.
The emitter manufacturer decides how fine the filtration has to be. Oklahoma State says manufacturers typically rate emitters by a screen mesh number or by the maximum filter opening width. Florida Extension gives a rule of thumb: remove particles down to a size four times smaller than the emitter passageway, so that grouping and bridging of particles doesn’t clog it. Organic particles with a density close to water’s tend to group and bridge more easily.
Sizing the filter #
A screen filter’s size is its effective area, meaning the area of the openings. Compared with the cross-section of the main pipe, a ratio of 2 or more is desirable. If the flow is large for the filtering surface, pressure losses rise, the filter wears out sooner and cleaning has to be frequent. Consider the water quality you need, the volume that must pass between cleanings, the filter area and the allowable pressure drop.
Cleaning #
You can clean a screen by hand, taking out the screen and washing it with clean water, but with dirty water that is impractical. Blowdown filters have a valve that diverts flow through the screen to flush out trapped particles without dismantling. The most convenient method is automatic flushing, triggered by the pressure difference across the filter, which grows as debris builds up. It can also run on a timer. Disk filters clean by backflushing: the pressure difference opens an exhaust valve and water flows backwards through the disks.
Never let dirt enter the system while you clean. Even small amounts of contamination can clog drip lines, so use filtered water for washing and backflushing, and Florida Extension strongly recommends secondary screen filters at the entrance to each subunit as a safety measure.
Minerals, algae and slime #
A publication2 covers the chemistry. If calcium is the problem, injecting acid to lower the pH prevents precipitates. Sometimes there isn’t enough calcium to precipitate in the water, yet enough to leave a lime crust over the emitter openings when the system shuts down and dries. In that case, injecting acid for the last few minutes before shutdown should help. If iron is the problem, oxidize it by chlorination or aeration and then filter the water. Because injected fertilizers and pesticides can also cause precipitation, put the filter after the injection point.
Algae seldom grow inside a system, because the components are opaque, but surface water often carries them, so filtration matters. Treating a pond that has algae with copper sulfate can reduce the filtration load. Bacterial slime can develop where the water has a lot of organic matter. A 2 ppm chlorine rinse at the end of each irrigation set normally prevents it, and if slime has already formed, a 30 ppm chlorine treatment will clean the system. Occasionally open the ends of the lateral lines and flush out accumulated sediment and precipitates.
Practical tips #
Test the water before choosing a filter. Get the emitter’s filtration rating from the maker and match it. Don’t skimp on filter size, because a small filter needs cleaning constantly and costs more in labor. Watch the pressure drop across the filter, since it tells you when cleaning is due, and keep a record. And inspect everything regularly, because a filter that fails quietly can let sediment into every lateral at once.
Sources and further reading #
- Screen Filters in Drip Irrigation Systems (AE61), University of Florida IFAS Extension
- Drip Irrigation Systems (BAE-1511), Oklahoma State University Extension