Center Pivot Application Calculator

Find out how much water your center pivot puts on per pass and per day, which timer setting gives the depth you want, and whether the system keeps up with your crop on the hottest days. It works with the percent timer or with hours per circle, for full and part circles, in US or metric units.

Center pivot application calculator

Net water applied per pass
–
Irrigated area
Gross depth per pass
Time per pass
Water pumped per pass
Same in US gallons
Net depth per day, running 24 h
Flow per unit area
Speed for your target
Capacity vs. crop demand

On a part circle the area and the time per pass shrink together, so the depth per pass stays the same, but the depth per day goes up. Gross depth is what leaves the sprinklers; net depth is what the efficiency you enter leaves in the root zone. The flow is taken as constant whether the end gun is on or off. 1 acre-inch = 27,154 US gallons (102.8 m³).

More on center pivots: Center Pivot Irrigation: Pros and Cons and the Center Pivot Maintenance Checklist.